Guide for the Vehicle Program Engineer

FROM
CF-JET Stakeholder Guide, 27 November 2026
READING TIME
4 min

Inlet temperature and loop pressure decide fit

Vehicle engineers decide whether a cooler meets thermal limits at the coolant temperature and pressure that the vehicle supplies. Hybrid combat vehicles convert 100 to 400 kW of electrical power, and at losses of 2.15 to 3 percent one conversion stage gives off 2 to 12 kW of heat. A stage at 12 kW is eight times the 1.5 kW design point (computed), so a full stage may need several plates or a larger plate, and the research recommends testing serial and parallel arrangements. The power density target rises from 3 kW/L today to 12 kW/L in future.

Inlet temperature is the largest uncertainty. Public Army documents give 65 °C as the current electronics inlet, and a 2019 GVSC briefing lists 85 °C as the current reference and 105 °C as the future requirement. A design validated at 65 °C loses 36 to 58 percent of its module capacity at 105 °C if its resistance is unchanged. The loop offers 2 to 5 psi (14 to 34 kPa) of pressure drop to electronics, and a 30 kPa cold plate uses most of it. Connecting three modules one after another at 4 L/min raises the inlet temperature of the third module by about 12 K. The research found no published XM30 inlet temperature.

Table 2 gives the vehicle engineer two parts: supplying the coolant conditions for the sub-array tests and reviewing the module results at inlet temperatures from 65 to 115 °C. The most useful contribution is a stated inlet temperature, pressure budget and flow for the test, because the research found none at module level in public documents.

Decisions and the evidence behind them

Table 6. Decisions for the vehicle program engineer

Decision What the research shows What is unproven Evidence
Coolant inlet temperature to design for Public Army documents give 65 °C as the current inlet and 80 to 105 °C as the future range. A design validated at 65 °C loses 36 to 58 percent of module capacity at 105 °C The XM30 inlet temperature; loop pressure at 115 °C; boiling at a 105 °C inlet Army documents and published studies; gaps stated
Pressure the cooler may use The loop offers 2 to 5 psi (14 to 34 kPa). The 30 kPa budget fits one module, and other components share the loop The share of the 30 kPa that the manifold uses Army documents; gap stated
Heat flux basis for comparing coolers Die-level heat flux is 12 to 24 times the footprint value The basis that a vehicle specification will use Published studies; computed
Weight, volume and pump power The research recommends reporting mass, coolant volume and pump power with every result Plate mass against copper and AlSi10Mg; weight and volume that vehicle thermal systems may use Gap stated

What to ask the team for

  • Junction-to-coolant resistance at inlet temperatures of 65, 85, 105 and 115 °C.

  • Pressure drop at each temperature, at both 4 and 8 L/min.

  • Heat flux on a footprint basis and on a die basis, since die-level flux is 12 to 24 times the footprint value.

  • Tests in serial and parallel arrangements, with the coolant rise and manifold pressure drop quoted for three-module installations.

  • Mass, coolant volume and pump power for each result.

  • Results at engine-off, low-flow conditions.

Frequently asked questions

At what coolant temperature has the design been shown to work?

The design point assumes 65 °C, and no measurement of the plate exists at any temperature. The research recommends resistance at 65, 85, 105 and 115 °C because capacity falls 36 to 58 percent when a design validated at 65 °C operates at 105 °C. Boiling at a 105 °C inlet is possible and has not been assessed.

Does the cooler fit the vehicle loop pressure?

A 30 kPa budget fits within the 14 to 34 kPa loop for a single module, and several modules, motors and a battery share the same loop. Printed channels come out smaller than designed, and a 19.5 percent undersize gives 2.4 times the pressure drop (computed), so the printed jet size is the main pressure risk. Jets under about 0.56 to 0.6 mm exceed 30 kPa.

Will the plate survive thermal cycling?

One aluminum silicon carbide plate cycled 1,800 times from −40 to 150 °C without failure. The AQG 324 qualification basis comes from automotive practice and contains no Army mission profile, so the research recommends cycles with swings of 75 to 125 °C and junction temperatures to 175 °C.

Does the plate help in engine-off operation?

No result exists. The research recommends low-flow testing, because silent-watch operation changes the coolant conditions that the vehicle supplies.

What heat loads should the engineer supply for sizing?

The open question is the heat load by component for vehicle microgrid power electronics and directed energy systems, and the coolant temperature that each receives. Component-level thermal budgets from GVSC and C5ISR programs would let the team size a demonstration to a vehicle need.

Studies to read first

These studies hold the sources, computed values and stated gaps behind the numbers in this guide. Evidence: Army briefings and peer-reviewed studies.

P1Thermal Management Demands of Silicon Carbide Power Electronics in Army Ground VehiclesA cold plate that dissipates 1,340 W per module with 25 °C coolant retains about 47 percent of that capacity at 105 °C coolant, the future Army engine-coolant temperature.P2Thermal Expansion Mismatch and Power Module ReliabilityAlSiC baseplates cut strain energy density to 0.18 MPa per cycle versus 1.94 MPa for copper; a tested AlSiC heat sink showed ≥18× lifetime.
ESC
CITE ·