SOL RESEARCHHUBZONE SMALL BUSINESSCAGE 44KM9Also on iOS & Android
STAKEHOLDER GUIDEROLE 5 OF 8

Guide for SOL's Principal Investigator and Engineers

FROM
CF-JET Stakeholder Guide, 27 November 2026
READING TIME
4 min

Validate the simulation before trusting the surrogate

SOL's engineers decide which test comes first and how much margin the design includes. The research recommends validating the simulation first. A surrogate model trained on simulation results reproduces the simulation error, which ranged from 1.6 to 39 percent depending on the closure and the quantity compared, and only measurements correct it. A single-jet measurement at the CF-JET diameter in the working fluid is the cheapest test that bounds the error. The predicted margin that results is 9.8 percent at a 15 percent error and 17.3 percent at a 30 percent error.

Design rules from the printing and carbon fiber research apply from the first drawing. Orient orifices along the build direction, keep jets over about 0.6 mm until nozzles are sized from measured CT data, add drain and access ports, and avoid bends. The process limits to enter in the optimization are a wall of about 0.3 mm and a fin of about 150 µm. The resistance budget is tight: a 1 mm insert at 36 W/m·K uses 28 of the 72 mm²·K/W budget, a 2 mm insert uses 55, and a 50 µm plastic skin uses 172, which exceeds the whole budget. The plated face of 10 to 25 µm must be the sealed face.

The AI toolkit that SOL proposes depends on calibrated uncertainty. A Gaussian process on a synthetic five-input problem placed 98.6 percent of points within ±5 percent at 200 training points, and its intervals covered 95.8 to 99.1 percent of points. Ensembles of five networks covered only 52.8 to 75.1 percent at a nominal 95 percent. An optimizer that searches for the best predicted design finds the points where such intervals fail. All benchmark values come from synthetic problems, so they test the software and say nothing about CF-JET hardware.

Figure 2 gives SOL the CFD comparison in the first stage and the lead in the sub-array stage, with a supporting part in the coupon and module stages. The sub-array is the stage where printed geometry, pressure drop and the AI toolkit meet, and the research recommends testing it with and without returns.

Decisions and the evidence behind them

Table 9. Decisions for SOL's principal investigator and engineers

Decision What the research shows What is unproven Evidence
Test the simulation first Area-averaged medians under 10 percent and maxima near 15 percent in air; 24.7 percent average and 39.3 percent local in a 2025 round-nozzle validation No comparison in water-glycol at the CF-JET jet size Peer-reviewed measurements; gap stated
Size the jets Jets under about 0.56 to 0.6 mm exceed 30 kPa. A horizontal 1 mm channel printed at 805 µm As-built nozzle size at 25 to 36 times the scale of printed precedents Peer-reviewed measurement; computed
Specify the insert Perpendicular fiber at 6 to 9 percent is needed for 50 W/m·K. Printed pitch fiber reached 36.63 W/m·K at 6.42 percent Conductivity of a 1 to 2 mm insert; fiber breakage in printing at 0.4 percent failure strain Peer-reviewed and vendor data; gap stated
Trust the surrogate to select designs Gaussian process intervals covered 95.8 to 99.1 percent of points; ensembles of five covered 52.8 to 75.1 percent Coverage on held-out CF-JET designs and measured points Computed benchmark on a synthetic problem; gap stated

What to ask the team for

  • Area-averaged and stagnation heat transfer reported separately, with the comparison error stated alongside the ASME V&V 20 validation uncertainty.

  • A defined case reference plane, and a crossflow ratio kept at about 0.3 or lower.

  • A pressure budget split by component: manifold, returns and jets.

  • A representative sub-array tested with and without returns in water-glycol at 65 °C and 4 to 8 L/min.

  • Ten to 20 paired designs at two mesh levels before a ladder of model tiers is adopted.

  • Each surrogate prediction labeled as interpolation or extrapolation.

  • About 13 replicates at each setting, which give a relative standard error of 20 percent in the estimated deviation (derived from normal theory).

  • Every new hardware batch scored against the current model before it joins the training set.

  • A release record that logs the solver version, mesh, closure, inputs and results for every simulation, and names the engineer who accepted each release.

Frequently asked questions

Which test comes first?

The single-jet comparison against the simulation, in water-glycol at the CF-JET jet size. It is the cheapest test and it sets the margin that every simulation-based prediction needs.

How much margin should the design include?

The research sets the predicted margin at 10 percent or more for the conduction shares it assumed. The computed values are 9.8 percent at a 15 percent error and 17.3 percent at a 30 percent error, and a root-sum-square of a 5 percent surrogate error and a 15 percent simulation error gives 15.8 percent.

Can the surrogate be trusted to select designs?

Only after its intervals are checked. No cooler study reports interval coverage, ensembles covered 52.8 to 75.1 percent in the benchmark, and a hybrid model covered 70.9 percent in a far region at 60 training points against a nominal 95 percent. The research recommends a Gaussian process for scalar outputs, coverage tests on held-out points and recalibration before the surrogate selects a design.

What interval width is acceptable?

The engineers set the criterion from the margin the budget leaves. A 10 percent interval on 0.02 K/W is 0.002 K/W, which equals 3 K of case-to-coolant rise at 1.5 kW (derived).

What should the first insert and skin use?

The research recommends a high-modulus fiber near 800 W/m·K with the tow conductivity measured, a sliced or pin-based insert for the 300 W/m·K case, and PEEK for the first builds. Jets should stay under 1 mm and the plated face should be tested at the intended velocity, because plating adhesion in hot glycol is unmeasured and pitch fiber breaks in printing at a 0.4 percent failure strain.

How many validation points are needed?

About 46 points separate 95 percent coverage from 85 percent coverage. Counts should be reported with intervals, batches pooled by region and measurements replicated.

Studies to read first

These studies hold the sources, computed values and stated gaps behind the numbers in this guide. Evidence: Peer-reviewed studies and computed benchmarks.

P4Engineering Design Under Sparse DataNine variables at three levels give 19,683 designs — 6,561× the three prototypes a typical program can build.S3Surrogate Modeling, Multi-Fidelity Learning, and Optimization for Thermal-Fluid DesignPublished cooler surrogates reproduce CFD within 0.2 to 2 percent after 20 to 100 simulations, so the ±5 percent target lies inside the reported range for smooth, low-dimensional design spaces.S4Uncertainty-Aware Neuro-Symbolic AI for Engineering DecisionsIn a computed benchmark, a physics rule plus learned correction predicted outside its training region with 3.1 percent error, against 7.0 percent for a learned model and 15.7 percent for the rule alone.S1Additively Manufactured Jet-Impingement Cold Plates with Interleaved ReturnsBest measured printed cooler: 21–35 mm²·K/W on 1 cm². CF-JET targets 36× that area — the gap this project closes.
ESC
CITE ·