University measurements are useful and capacity has gaps
Co-investigators decide which measurements their laboratories can commit to and publish. The research identifies work that suits a university: single-jet validation, through-thickness conductivity of carbon fiber coupons, thermal expansion of the finished plate, micro-CT of printed and plated parts, and coupon builds. Capacity named in the research includes CT at Auburn University, additive manufacturing laboratories at Calhoun, Mississippi Gulf Coast and East Mississippi community colleges, and printing and materials work at Alabama A&M, Tuskegee and Jackson State. No retrieved source documents a flow loop, laser flash or thermal cycling at an HBCU or community college.
Funding rules decide who is paid. The HBCU and minority-institution vehicles retrieved fund institutions only. The 2026 pilot expects fundamental research, funds no equipment and bars subawards, and its applications closed on 10 April 2026. A university that holds an award can collaborate with SOL on research that the award funds, and any exchange of data or software then needs a written agreement that states what each party contributes.
In Figure 2 the co-investigator leads the single-jet rig and supports the coupon, sub-array and module stages. The rig is the cheapest measurement in the sequence, and its result sets the margin for every simulation-based prediction that follows.
Decisions and the evidence behind them
Table 7. Decisions for the university co-investigator
| Decision | What the research shows | What is unproven | Evidence |
|---|---|---|---|
| Which tests to commit to | A single-jet rig can be built as a teaching project, and Auburn University holds CT capacity | No flow loop, laser flash or thermal cycling is documented at an HBCU or community college | Capacity survey in the research; gap stated |
| How to measure conductivity through the plate | A regression on five thicknesses recovered conductivity where single-specimen readings gave 33 to 75 percent of the true value in a model | Conductivity of perpendicular pitch fiber inserts at several pitches; lateral diffusion in laser flash | Computed; gap stated |
| Which defects to look for by CT | A 30 µm voxel detects features of 90 µm; 5 µm scans of sub-regions find the pore population | Whether CT detects voids and delamination in the plated face and its bond to the body | Computed; gap stated |
| What to publish | Fundamental research rules protect the publication of basic research on campus | No source classifies a cold plate for export control | Regulations; gap stated |
What to ask the team for
A written statement of the tests the laboratory is asked to perform, with voxel size, flow rate and temperature for each.
Coupons built like the plate, with the interface material and contact pressure recorded for each measurement.
Measurement of thermal expansion on the finished plate from 25 to 175 °C.
A scoping visit to confirm equipment, because the capacity survey found no documented flow loop.
A written agreement on the ownership of baseline software and data before students begin work.
Frequently asked questions
Can faculty and students publish results?
Fundamental research rules protect the publication of basic research performed on campus, and the research cites National Security Decision Directive 189 and the exclusion at 15 C.F.R. § 734.8, together with the public domain provision at ITAR 120.34. Physical items and work outside the campus are treated differently, and no source classifies a cold plate for export control. The sponsored-programs and research-security offices should confirm the status before the first publication.
What can a community college or HBCU laboratory contribute?
Printing and materials work, coupon builds and, with a scoping visit, a single-jet rig. The research proposes the rig as a teaching project, which lets students build and operate a measurement that the first test stage needs.
Which research questions are open?
The through-thickness conductivity of plates with perpendicular pitch fiber inserts at several pitches, and the best measurement method. Whether laser flash shows lateral diffusion that breaks the one-dimensional model. Whether micro-CT detects voids and delamination in the plated face and its bond. How many validation plates each region needs, given that 46 points separate 95 percent coverage from 85 percent coverage.
How are data rights decided?
The contract vehicle decides. SBIR and STTR awards protect data for 20 years and then give the Government perpetual government purpose rights, and no source states proof-of-ownership requirements for software baselines.